Geodesic Dome Vent CFD Analysis (Soleimani et al., 2018)

Overview

Authors: Zohreh Soleimani (University of Bath), John Kaiser Calautit, Katrina Calautit (University of Nottingham), Ben Richard Hughes (University of Sheffield). Published in ICE Engineering Sustainability, Vol. 171(8), 2018.

Comprehensive CFD analysis of a naturally ventilated geodesic dome building across all 12 months in Yazd, Iran (BWh hot desert climate). Uses ANSYS FLUENT15 with standard k-epsilon turbulence model, 4.67M element unstructured mesh.

Dome Specification

Critical Finding: Summer Cooling Failure

Roof vent alone acts as "air curtain" — it supplies fresh air but does NOT effectively exhaust warm air. During summer months (38-41°C outdoor), PMV values all above +3 (Hot on ASHRAE scale). Natural ventilation through roof vents alone cannot satisfy thermal requirements.

Thermal Data

Why It Fails

Roof vent creates swirling recirculation flows on upper floor, producing uneven thermal and airflow distribution between floors. The vent captures approaching airflow and redirects to leeward wall, forming large recirculation rather than effective exhaust.

  1. Lower openings must be added to complement roof vents (enable stack effect through-flow)
  2. Divider in roof vent could improve ventilation strategy (separate inlet/outlet zones)
  3. Inlet and outlet shafts could improve flow directionality
  4. Thermal mass with night cooling for summer performance
  5. Evaporative cooling, heat pipes, PCMs, or desiccant dehumidification for hot-humid climates

Arched Roof Vent Optimization (Li et al., 2020)

A companion study on arched (curved-roof) greenhouses demonstrates what optimized vent placement achieves:

This demonstrates that vent type and position angle optimization on curved roofs can yield dramatic improvements — the approach the dome studies call for but do not perform.