BUCKYVERSE

Spherical PCM Modules and Dome Thermal Battery Performance

Spherical PCM Modules (Huluka & Muthulingam, 2025)

Published in Scientific Reports, Vol. 15, Article 39845 (November 2025).

Experiment

Reinforced concrete roof slab (1.325 × 1.325 × 0.15 m) divided into four thermally isolated zones:

  1. Conventional concrete (control)
  2. Empty spherical modules
  3. Modules filled with OM35 (organic PCM, 35°C melting point)
  4. Modules filled with OM37 (37°C melting point)

Forged aluminum (Al 1200) semi-spherical bowls welded together. 354-358g of liquid PCM, occupying 75% of sphere diameter. Testing in Rupnagar, India (subtropical), April, J-type thermocouples at 1-minute intervals.

Results

Zone Cooling Load Reduction Surface Temp Decrease Decrement Factor
1 (control) — — 0.56
2 (empty spheres) 59% — 0.50
3 (OM35) 68% up to 11.1°C 0.38
4 (OM37) 69% min 9.2°C, avg 10.2°C 0.37

Critical Geometric Finding

Spherical and cylindrical PCM shapes provide a 70% increase in energy efficiency compared to rectangular designs. This is directly transferable to dome shell geometry — curved encapsulation outperforms flat.

Mechanism

PCM modules undergo daily phase transitions: absorbing heat as latent heat during melting (daytime) and releasing during solidification (nighttime), creating a self-regulating thermal cycle.

Monolithic Dome Thermal Battery

Source: Monolithic Dome Institute (monolithic.org).

Existing Thermal Mass Performance

Domes already function as "very large thermal storage" systems:

Energy Performance

Night Cooling = PCM Analog

"In many parts of the country, it is possible to cool the thermal mass of the shell by utilizing fresh air." This night-cooling-of-thermal-mass strategy is essentially the same operational principle as PCM night solidification, suggesting PCMs would integrate naturally.

The Untested Combination

No published study examines PCM integration with dome or curved-shell geometry. The gap exists at the intersection of:

  1. PCM in building envelopes: 2-11°C temperature reductions, 15-69% cooling load savings (well-studied in flat roofs)
  2. Dome thermal performance: 50-75% energy savings, massive thermal inertia (industry data)

Predicted synergy: